AUTOLOGOUS ARTERIOVENOUS FISTULA
Autologous Arteriovenous Fistula

In patients undergoing chronic hemodialysis, the need for a vascular access (VA) that functions adequately for a long time and without significant complications, is a matter of critical importance for the quality of life and survival of these patients.

In the early 1960s, external shunt or Scribner shunt was originally used to perform hemodialysis in patients with end stage renal disease (ESRD). Despite the modifications and improvements made, complications such as inflammation, thrombosis and bleeding continued to occur at a high frequency.
VA got its current form in 1966 by surgical construction of an internal arteriovenous fistula (AVF). Since then, various improvements and innovations have brought other types of VA into daily clinical practice, such as arteriovenous grafts AVG and various types of central venous catheters (CVC). Autologous arteriovenous fistula (AVF) is constructed by subcutaneous anastomosis of an artery with an adjacent vein, allowing blood to flow directly from the artery to the vein (bypassing the capillary circulation), resulting in a vein arterialisation due to the high flows and pressures of the arterial circulation. The most common types of AVF are:

1The radial-cephalic AVF, which is constructed by anastomosis of the radial artery with the cephalic vein in the wrist, resulting in the creation of a superficial arterialised vein of satisfactory length along the forearm, suitable for puncture.

2The brachial-cephalic AVF in the upper arm at the level of the elbow between the brachial artery and the cephalic vein, resulting in the creation of a vessel suitable for cannulation along the arm.

3The brachial-basilic AVF also in the upper arm, between the brachial artery and the basilic vein. Because of the formation of an arterialised vein that is not found as superficially as required for puncture (> 6 mm from the surface of the skin), the basilic vein is usually translocated to a more superficial position. This technique results in a large incision along almost the whole upper arm and is performed under local anesthesia (basilic vein transposition).

The AVF anastomosis may be either side-to-side (such as the original type described by Brescia and Cimino in radial-cephalic anastomosis) or end-to- side (side of the artery- end of the vein). In both cases, the peripheral blood flow is maintained through the artery. In the side-to-side method, the increased arterial pressure can be transmitted to the venous system of the hand with subsequent edema formation. With the end to side anastomosis, this complication is limited due to ligation of the distal part of the vein. The autologous AVFs have a primary failure rate of about 20% (varies from 10-50%) which depends on the experience of each center.

Once the anastomosis has matured, the long-term patency rates are excellent and range from about 85% in the first year to 75% at 2 years, and with a low incidence of infection. Stenosis is the major cause of thrombosis of an AVF, and in case of a radial-cephalic AVF it is often located around the anastomosis area, whereas in the AVF made in the arm, stenosis is usually located more distally.

After the surgical construction of the AVF, at least one month is required for cannulation, while according to the Kidney Dialysis Outcomes Quality Initiative (K/DOQI) guidelines, the first puncture should not be attempted earlier than 6-8 weeks.

Bibliography

  1. Quinton W, Dillard D, Scribner BH. Cannulation of blood vessels for prolonged hemodialysis. Trans Am Soc Artif Intern Organs 1960; 6: 114-113).
  2. Brescia MJ, Cimino JE, Appel K, Hurwich BJ. Chronic hemodialysis using venipuncture and a surgically created arteriovenous fistula. N Engl J Med 1966; 275: 10891092.
  3. Harland RC. Placement of permanent vascular access devices: Surgical consideration. Adv Renal Replace Ther 1994; 1: 99-106.
  4. Kinnaert P, Vereerstraeten P, Toussaint C, Van Geertruyden J et al. Nine years’ experience with internal arteriovenous fistulas for hemodialysis: A study of some factors influencing the results. Br J Surg 1977; 64: 242-246.
  5. Tordoir JH, Dammers R, De Brauw M. Video-assisted basilic vein transposition for hemodialysis vascular access: preliminary experience with a new technique. Nephrol Dial Transplant 2001; 16(2): 391-394.
  6. Palder SB, Kirkman RL, Whittemore AD, Hakim RM et al. Vascular access for hemodialysis. Patency rates and results of revision. Ann Surg 1985; 202(2): 235-239.
  7. Malovrh M. Native arteriovenous fistula: preoperative evaluation. Am J Kidney Dis 2002; 39 (6): 1218-1225.
  8. Schwab SJ, Harrington JT, Singh A et al. Vascular access for hemodialysis [clinical conference]. Kidney Int 1999; 55 (5): 2078-2090.
  9. Albers FJ. Causes of hemodialysis access failure. Adv Ren Replace Ther 1994; 1(2):107118.
  10. Turmel-Rodrigues L, Pengloan J, Baudin S et al. Treatment of stenosis and thrombosis in hemodialysis fistulas and grafts by interventional radiology. Nephrol Dial Transplant 2000; 15(12): 2029-2036.
  11. Saran R, Dykstra DM, Pisoni RL, et al. Timing of first cannulation and vascular access in hemodialysis: an analysis of practice patterns at dialysis facilities in the DOPPS. Nephrol Dial Transplant 2004; 19(9): 2334-2340.
  12. National Kidney Foundation: K/DOQI clinical practice guidelines in vascular access: 2006 update. Am J Kidney Dis 2006; 48 [Suppl 1]: S176-S306.
Leivaditis Konstantinos MD, PhD
Demirtzi Paraskevi MD

Nephrologists, “NEPHROXENIA” Chalkidiki Dialysis Centre

NEPHROXENIA DIALYSIS CENTERS ARE DESIGNED SPECIFICALLY AROUND THE NEEDS OF A CONTEMPORARY RENAL PATIENT.
IN NEPHROXENIA YOU CAN COMBINE WORLD CLASS DIALYSIS WITH AMAZING HOLIDAYS.
Privacy Preferences
When you visit our website, it may store information through your browser from specific services, usually in form of cookies. Here you can change your privacy preferences. Please note that blocking some types of cookies may impact your experience on our website and the services we offer.